Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Drug Test Anal ; 16(1): 99-104, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37173289

RESUMO

Whipped cream canisters, also known as nitrous oxide whippets, are traditionally used in the culinary arts to prepare food foams. In recent years, however, these gas canisters have been cracked open and inhaled to produce a "legal" high. Users of these whippets have reported the presence of an oily residue containing metallic particles. This contamination was investigated using liquid chromatography-, gas chromatography- and inductively coupled plasma-mass spectrometry (ICP-MS) and optical emission spectrometry (ICP-OES). The particulate matter was also analyzed by scanning transmission electron microscopy (STEM) combined with energy-dispersive X-ray spectroscopy (EDX). The presence of cyclohexyl isothiocyanate was confirmed at a maximum concentration of 67 µg per whippet. ICP-MS and ICP-OES analysis revealed the presence of mainly iron and zinc, but also, traces of aluminum, chromium, cobalt, nickel, and lead were found. STEM-EDX analysis confirmed the presence of nano-sized particles containing iron and zinc. When simulating inhalation, using the multiple path particle dosimetry model, it was confirmed that these nano-sized particles can reach the deeper parts of the lungs. Most users assume that inhaling a food-grade nitrous oxide whippet for a "legal" high poses no risks. However, this research shows that users are exposed to cyclohexyl isothiocyanate, a substance classified as a respiratory sensitizer. The presence of zinc in the particulate matter could potentially be linked to lung lesions.


Assuntos
Drogas Ilícitas , Óxido Nitroso , Cromatografia Gasosa-Espectrometria de Massas , Zinco , Ferro , Material Particulado , Isotiocianatos
2.
Sci Total Environ ; 870: 161889, 2023 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-36731552

RESUMO

Silver-based biocides are applied in face masks because of their antimicrobial properties. The added value of biocidal silver treatment of face masks to control SARS-CoV-2 infection needs to be balanced against possible toxicity due to inhalation exposure. Direct measurement of silver (particle) release to estimate exposure is problematic. Therefore, this study optimized methodologies to characterize silver-based biocides directly in the face masks, by measuring their total silver content using ICP-MS and ICP-OES based methods, and by visualizing the type(s) and localization of silver-based biocides using electron microscopy based methods. Thirteen of 20 selected masks intended for general use contained detectable amounts of silver ranging from 3 µg to 235 mg. Four of these masks contained silver nanoparticles, of which one mask was silver coated. Comparison of the silver content with limit values derived from existing inhalation exposure limits for both silver ions and silver nanoparticles allowed to differentiate safe face masks from face masks that require a more extensive safety assessment. These findings urge for in depth characterization of the applications of silver-based biocides and for the implementation of regulatory standards, quality control and product development based on the safe-by-design principle for nanotechnology applications in face masks in general.


Assuntos
COVID-19 , Desinfetantes , Nanopartículas Metálicas , Humanos , Prata , COVID-19/prevenção & controle , Máscaras , SARS-CoV-2
3.
Nanomaterials (Basel) ; 12(4)2022 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-35215053

RESUMO

In single particle inductively coupled plasma mass spectrometry (spICP-MS), the transport efficiency is fundamental for the correct determination of both particle number concentration and size. In the present study, transport efficiency was systematically determined on three different days with six carefully characterised gold nanoparticle (AuNP) suspensions and in seven European and US expert laboratories using different ICP-MS instruments and spICP-MS software. Both particle size-(TES)-and particle frequency-(TEF)-methods were applied. The resulting transport efficiencies did not deviate much under ideal conditions. The TEF method however systematically resulted in lower transport efficiencies. The extent of this difference (0-300% rel. difference) depended largely on the choice and storage conditions of the nanoparticle suspensions used for the determination. The TES method is recommended when the principal measurement objective is particle size. If the main aim of the measurement is the determination of the particle number concentration, the TEF approach could be preferred as it might better account for particle losses in the sample introduction system.

4.
Sci Rep ; 12(1): 2529, 2022 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-35169246

RESUMO

Although titanium dioxide (TiO2) is a suspected human carcinogen when inhaled, fiber-grade TiO2 (nano)particles were demonstrated in synthetic textile fibers of face masks intended for the general public. STEM-EDX analysis on sections of a variety of single use and reusable face masks visualized agglomerated near-spherical TiO2 particles in non-woven fabrics, polyester, polyamide and bi-component fibers. Median sizes of constituent particles ranged from 89 to 184 nm, implying an important fraction of nano-sized particles (< 100 nm). The total TiO2 mass determined by ICP-OES ranged from 791 to 152,345 µg per mask. The estimated TiO2 mass at the fiber surface ranged from 17 to 4394 µg, and systematically exceeded the acceptable exposure level to TiO2 by inhalation (3.6 µg), determined based on a scenario where face masks are worn intensively. No assumptions were made about the likelihood of the release of TiO2 particles itself, since direct measurement of release and inhalation uptake when face masks are worn could not be assessed. The importance of wearing face masks against COVID-19 is unquestionable. Even so, these results urge for in depth research of (nano)technology applications in textiles to avoid possible future consequences caused by a poorly regulated use and to implement regulatory standards phasing out or limiting the amount of TiO2 particles, following the safe-by-design principle.


Assuntos
Máscaras , Espectrofotometria Atômica , Titânio/análise , COVID-19/prevenção & controle , COVID-19/virologia , Humanos , Exposição por Inalação/análise , Nanopartículas Metálicas/química , Microscopia Eletrônica de Transmissão , Tamanho da Partícula , SARS-CoV-2/isolamento & purificação , Controle Social Formal , Têxteis/análise
5.
Vaccines (Basel) ; 9(7)2021 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-34358174

RESUMO

Recombinant Newcastle disease viruses (rNDV) have been used as bivalent vectors for vaccination against multiple economically important avian pathogens. NDV-vectored vaccines expressing the immunogenic H5 hemagglutinin (rNDV-H5) are considered attractive candidates to protect poultry from both highly pathogenic avian influenza (HPAI) and Newcastle disease (ND). However, the impact of the insertion of a recombinant protein, such as H5, on the biological characteristics of the parental NDV strain has been little investigated to date. The present study compared a rNDV-H5 vaccine and its parental NDV LaSota strain in terms of their structural and functional characteristics, as well as their recognition by the innate immune sensors. Structural analysis of the rNDV-H5 demonstrated a decreased number of fusion (F) and a higher number of hemagglutinin-neuraminidase (HN) glycoproteins compared to NDV LaSota. These structural differences were accompanied by increased hemagglutinating and neuraminidase activities of rNDV-H5. During in vitro rNDV-H5 infection, increased mRNA expression of TLR3, TLR7, MDA5, and LGP2 was observed, suggesting that the recombinant virus is recognized differently by sensors of innate immunity when compared with the parental NDV LaSota. Given the growing interest in using NDV as a vector against human and animal diseases, these data highlight the importance of thoroughly understanding the recombinant vaccines' structural organization, functional characteristics, and elicited immune responses.

6.
Food Control ; 120: 107550, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33536722

RESUMO

Titanium dioxide is a white colourant authorised as food additive E 171 in the EU, where it is used in a range of alimentary products. As these materials may contain a fraction of particulates with sizes below 100 nm and current EU regulation requires specific labelling of food ingredient to indicate the presence of engineered nanomaterials there is now a need for standardised and validated methods to appropriately size and quantify (nano)particles in food matrices. A single-particle inductively coupled plasma mass spectrometry (spICP-MS) screening method for the determination of the size distribution and concentration of titanium dioxide particles in sugar-coated confectionery and pristine food-grade titanium dioxide was developed. Special emphasis was placed on the sample preparation procedure, crucial to reproducibly disperse the particles before analysis. The transferability of this method was tested in an interlaboratory comparison study among seven experienced European food control and food research laboratories equipped with various ICP-MS instruments and using different software packages. The assessed measurands included the particle mean diameter, the most frequent diameter, the percentage of particles (in number) with a diameter below 100 nm, the particles' number concentration and a number of cumulative particle size distribution parameters (D0, D10, D50, D99.5, D99.8 and D100). The evaluated method's performance characteristics were, the within-laboratory precision, expressed as the relative repeatability standard deviation (RSDr), and the between-laboratory precision, expressed as the relative reproducibility standard deviation (RSDR). Transmission electron microscopy (TEM) was used as a confirmatory technique and served as the basis for bias estimation. The optimisation of the sample preparation step showed that when this protocol was applied to the relatively simple sample food matrices used in this study, bath sonication turned out to be sufficient to reach the highest, achievable degree of dispersed constituent particles. For the pristine material, probe sonication was required. Repeatability and reproducibility were below 10% and 25% respectively for most measurands except for the lower (D0) and the upper (D100) bound of the particle size distribution and the particle number concentration. The broader distribution of the lower and the upper bounds could be attributed to instrument-specific settings/setups (e.g. the timing parameters, the transport efficiency, type of mass-spectrometer) and software-specific data treatment algorithms. Differences in the upper bound were identified as being due to the non-harmonised application of the upper counting limit. Reporting D99.5 or D99.8 instead of the effectively largest particle diameter (D100) excluded isolated large particles and considerably improved the reproducibility. The particle number-concentration was found to be influenced by small differences in the sample preparation procedure. The comparison of these results with those obtained using electron microscopy showed that the mean and median particle diameter was, in all cases, higher when using spICP-MS. The main reason for this was the higher size detection limit for spICP-MS plus the fact that some of the analysed particles remained agglomerated/aggregated after sonication. Single particle ICP-MS is a powerful screening technique, which in many cases provides sufficient evidence to confirm the need to label a food product as containing (engineered) titanium dioxide nanomaterial according to the current EU regulatory requirements. The overall positive outcome of the method performance evaluation and the current lack of alternative standardised procedures, would indicate this method as being a promising candidate for a full validation study.

7.
Artigo em Inglês | MEDLINE | ID: mdl-32946346

RESUMO

Silver (E174) is authorised as a food additive in the EU. The unknown particle size distribution of E174 is a specific concern for the E174 risk assessment. This study characterised the fraction of silver (nano)particles in 10 commercially available pristine E174 food additives and 10 E174-containing products by transmission electron microscopy (TEM) and single-particle inductively coupled plasma-mass spectrometry (spICP-MS). TEM analysis showed that all samples contained micrometre-sized flakes and also a fraction of (nano)particles. Energy-dispersive X-ray spectroscopy (EDX) and electron diffraction confirmed that the (nano)particles and micrometre-sized flakes consisted of silver. A higher amount of (nano)particles was observed in the products than in the food additives. In addition, the surface of the micrometre-sized flakes was rougher in products. The median of the minimum external dimension, assessed as minimal Feret diameter, of the fraction of (nano)particles determined by quantitative TEM analysis was 11 ± 4 nm and 18 ± 7 nm (overall mean ± standard deviation), for food additives and products, respectively. Similar size distributions were obtained by spICP-MS and TEM, considering the limit of detection of spICP-MS. The median of the equivalent spherical diameter of the fraction of (nano)particles determined by spICP-MS was 19 ± 4 nm and 21 ± 2 nm (overall mean ± standard deviation), for food additives and products, respectively. In all samples, independent of the choice of technique, the nano-sized particles represented more than 97% (by number) of the silver particles, even though the largest mass of silver was present as flakes.


Assuntos
Aditivos Alimentares/química , Nanopartículas Metálicas/química , Prata/química , Acetona/química , Doces , Espectrometria de Massas , Microscopia Eletrônica de Transmissão , Tamanho da Partícula , Povidona/química , Medição de Risco , Cloreto de Sódio/química
8.
Nanomaterials (Basel) ; 10(3)2020 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-32213951

RESUMO

E171 (titanium dioxide) is a food additive that has been authorized for use as a food colorant in the European Union. The application of E171 in food has become an issue of debate, since there are indications that it may alter the intestinal barrier. This work applied standardized and validated methodologies to characterize representative samples of 15 pristine E171 materials based on transmission electron microscopy (TEM) and single-particle inductively coupled plasma mass spectrometry (spICP-MS). The evaluation of selected sample preparation protocols allowed identifying and optimizing the critical factors that determine the measurement of the particle size distribution by TEM. By combining optimized sample preparation with method validation, a significant variation in the particle size and shape distributions, the crystallographic structure (rutile versus anatase), and the physicochemical form (pearlescent pigments versus anatase and rutile E171) was demonstrated among the representative samples. These results are important for risk assessment of the E171 food additive and can contribute to the implementation of the European Food Safety Authority (EFSA) guidance on risk assessment of the application of nanoscience and nanotechnologies in the food and feed chain.

9.
Environ Toxicol Pharmacol ; 73: 103266, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31707308

RESUMO

The toxicological potential of halloysite nanotubes (HNTs) and variants after functional alterations to surface area are not clear. We assessed the toxicological response to HNTs (NaturalNano (NN)) before and after surface etching (NN-etched). Potential cytotoxicity of the two HNTs was screened in vitro in MutaTMMouse lung epithelial cells. Lung inflammation, acute phase response and genotoxicity were assessed 1, 3, and 28 days after a single intratracheal instillation of adult female C57BL/6 J BomTac mice. The doses were 6, 18 or 54 µg of HNTs, compared to vehicle controls and the Carbon black NP (Printex 90) of 162 µg/mouse. The cellular composition of bronchoalveolar lavage (BAL) fluid was determined as a measure of lung inflammation. The pulmonary and hepatic acute phase responses were assessed by Serumamyloida mRNA levels in lung and liver tissue by real-time quantitative PCR. Pulmonary and systemic genotoxicity were analyzed by the alkaline comet assay as DNA strand breaks in BAL cells, lung and liver tissue. The etched HNT (NN-etched) had 4-5 times larger BET surface area than the unmodified HNT (NN). Instillation of NN-etched at the highest dose induced influx of neutrophils into the lungs at all time points and increased Saa3 mRNA levels in lung tissue on day 1 and 3 after exposure. No genotoxicity was observed at any time point. In conclusion, functionalization by etching increased BET surface area of the studied NN and enhanced pulmonary inflammatory toxicity in mice.


Assuntos
Reação de Fase Aguda , Argila , Pulmão/efeitos dos fármacos , Nanotubos/toxicidade , Animais , Líquido da Lavagem Broncoalveolar , Ensaio Cometa , Camundongos , Camundongos Endogâmicos C57BL , Nanotubos/química , Pneumonia
10.
Materials (Basel) ; 12(17)2019 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-31443380

RESUMO

E174 (silver) is a food additive that may contain silver nanoparticles (AgNP). Validated methods are needed to size and quantify these particles in a regulatory context. However, no validations have yet been performed with food additives or real samples containing food additives requiring a sample preparation step prior to analysis. A single-particle inductively coupled plasma mass spectrometry (spICP-MS) method was developed and validated for sizing and quantifying the fraction of AgNP in E174 and in products containing E174, and associated uncertainties related to sample preparation, analysis and data interpretation were unraveled. The expanded measurement uncertainty for AgNP sizing was calculated to be 16% in E174-containing food products and increased up to 23% in E174 itself. The E174 food additives showed a large silver background concentration combined with a relatively low number of nanoparticles, making data interpretation more challenging than in the products. The standard uncertainties related to sample preparation, analysis, and challenging data interpretation were respectively 4.7%, 6.5%, and 6.0% for triplicate performances. For a single replicate sample, the uncertainty related to sample preparation increased to 6.8%. The expanded measurement uncertainty related to the concentration determination was 25-45% in these complex samples, without a clear distinction between additives and products. Overall, the validation parameters obtained for spICP-MS seem to be fit for the purpose of characterizing AgNP in E174 or E174-containing products.

11.
Materials (Basel) ; 12(14)2019 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-31311143

RESUMO

An approach for the size measurement of particulate (nano)materials by transmission electron microscopy was evaluated. The approach combines standard operating procedures for specimen preparation, imaging, and image analysis, and it was evaluated on a series of certified reference materials and representative test materials with varying physical properties, including particle size, shape, and agglomeration state. The measurement of the median value of the minimal external particle diameter distribution was intra-laboratory validated. The validation study included an assessment of the limit of detection, working range, selectivity, precision, trueness, robustness, and ruggedness. An uncertainty that was associated to intermediate precision in the range of 1-7% and an expanded measurement uncertainty in the range of 7-20% were obtained, depending on the material and image analysis mode. No bias was observed when assessing the trueness of the approach on the certified reference materials ERM-FD100 and ERM-FD304. The image analysis method was validated in an inter-laboratory study by 19 laboratories, which resulted in a within-laboratory precision in the range of 2-8% and a between-laboratory precision of between 2% and 14%. The automation and standardization of the proposed approach significantly improves labour and cost efficiency for the accurate and precise size measurement of the particulate materials. The approach is shown to be implementable in many other electron microscopy laboratories.

12.
Toxicol In Vitro ; 28(1): 60-9, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23811260

RESUMO

Toxicological characterization of manufactured nanomaterials (NMs) is essential for safety assessment, while keeping pace with innovation from their development and application in consumer products. The specific physicochemical properties of NMs, including size and morphology, might influence their toxicity and have impact on human health. The present work aimed to evaluate the genotoxicity of nanosized titanium dioxide (TiO2), synthetic amorphous silica (SAS) and multiwalled carbon nanotubes (MWCNTs), in human lymphocytes. The morphology and size of those NMs were characterized by transmission electron microscopy, while the hydrodynamic particle size-distributions were determined by dynamic light scattering. Using a standardized procedure to ensure the dispersion of the NMs and the cytokinesis-block micronucleus assay (without metabolic activation), we observed significant increases in the frequencies of micronucleated binucleated cells (MNBCs) for some TiO2 NMs and for two MWCNTs, although no clear dose-response relationships could be disclosed. In contrast, all forms of SAS analyzed in this study were unable to induce micronuclei. The present findings increase the weight of evidence towards a genotoxic effect of some forms of TiO2 and some MWCNTs. Regarding safety assessment, the differential genotoxicity observed for closely related NMs highlights the importance of investigating the toxic potential of each NM individually, instead of assuming a common mechanism and equal genotoxic effects for a set of similar NMs.


Assuntos
Testes de Mutagenicidade/métodos , Nanotubos de Carbono/toxicidade , Dióxido de Silício/toxicidade , Titânio/toxicidade , Adulto , Feminino , Humanos , Técnicas In Vitro , Luz , Linfócitos/efeitos dos fármacos , Linfócitos/metabolismo , Masculino , Testes para Micronúcleos , Microscopia Eletrônica de Transmissão , Nanoestruturas/toxicidade , Nanotubos de Carbono/química , Tamanho da Partícula , Espalhamento de Radiação , Dióxido de Silício/química , Titânio/química
13.
Reprod Toxicol ; 41: 86-97, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23714338

RESUMO

We studied the effects of preconceptional exposure to multiwalled carbon nanotubes (MWCNTs): mature, female C57BL/6J mice were intratracheally instilled with 67µg NM-400 MWCNT, and the following day co-housed with mature males, in breeding pairs. Time to delivery of the first litter, litter parameters, maternal inflammation and histopathology of lung and liver were recorded. In male offspring, locomotor activity, startle response, and daily sperm production (DSP) were assessed. In the dams, lung and liver bore evidence of MWCNT exposure when assessed 6 weeks and 4 months after exposure. A short delay in the delivery of the first litter was observed in exposed females. Litter parameters, behavior and DSP were similar in control and exposed groups. In conclusion, instillation of a single dose of MWCNT induced long lasting pathological changes in dam lung and liver. Theoretically, lung inflammation due to particle exposure could interfere with female reproductive parameters. Whether the observed lag in delivery of a first litter was in fact caused by exposure to MWCNT should be addressed in a study designed specifically to elucidate effects on the early processes involved in establishment of pregnancy. Exposure was not associated with changes in the assessed gestational or offspring parameters.


Assuntos
Fígado/efeitos dos fármacos , Pulmão/efeitos dos fármacos , Nanotubos de Carbono/toxicidade , Pneumonia/induzido quimicamente , Animais , Líquido da Lavagem Broncoalveolar/citologia , Feminino , Fertilidade/efeitos dos fármacos , Fígado/patologia , Pulmão/patologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Atividade Motora/efeitos dos fármacos , Pneumonia/patologia , Gravidez , Reflexo de Sobressalto/efeitos dos fármacos , Espermatogênese/efeitos dos fármacos
14.
J Nanobiotechnology ; 10: 24, 2012 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-22709926

RESUMO

BACKGROUND: The interaction of a nanomaterial (NM) with a biological system depends not only on the size of its primary particles but also on the size, shape and surface topology of its aggregates and agglomerates. A method based on transmission electron microscopy (TEM), to visualize the NM and on image analysis, to measure detected features quantitatively, was assessed for its capacity to characterize the aggregates and agglomerates of precipitated and pyrogenic synthetic amorphous silicon dioxide (SAS), or silica, NM. RESULTS: Bright field (BF) TEM combined with systematic random imaging and semi-automatic image analysis allows measuring the properties of SAS NM quantitatively. Automation allows measuring multiple and arithmetically complex parameters simultaneously on high numbers of detected particles. This reduces operator-induced bias and assures a statistically relevant number of measurements, avoiding the tedious repetitive task of manual measurements. Access to multiple parameters further allows selecting the optimal parameter in function of a specific purpose.Using principle component analysis (PCA), twenty-three measured parameters were classified into three classes containing measures for size, shape and surface topology of the NM. CONCLUSION: The presented method allows a detailed quantitative characterization of NM, like dispersions of precipitated and pyrogenic SAS based on the number-based distributions of their mean diameter, sphericity and shape factor.


Assuntos
Precipitação Química , Microscopia Eletrônica de Transmissão/métodos , Nanoestruturas/química , Dióxido de Silício/química , Temperatura , Nanoestruturas/ultraestrutura , Tamanho da Partícula , Análise de Componente Principal , Software , Sonicação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...